Description
Features:
- Available in DLCA NET, DLCA NET-Slim and DLCA NET-IP65 models
- Single and dual channel versions
- Left and right load cell inputs allow tension monitoring on each side of the web (single channel version)
- Two programmable alarms
- Dual Ethernet ports
- Accessible from any PLC that communicates over EtherNet/IP, PROFINET, Modbus TCP, EtherCAT or embedded web server page
- Rockwell AOP (add on profile)
- DLR (Device Level Ring)
- PTPv2 and PTPv1
- Relay output that signals “ready to run” (DLCA NET)
- Six-segment display (DLCA NET)
- Analog outputs for left, right and total tensions (DLCA NET)
- All tensions, ready to run signal and alarm outputs via communications only (DLCA NET-Slim and DLCA NET-IP65)
- Available software tools for tension data recording and configuration backup
DLCA-NET SPECIFICATIONS
- Power Supply24 VDC, +/- 10%, 250mA maximum
- Tension Load Cell Signal Input (Single Channel)1 or 2 load cells from a single tension zone, connected to a left and right input
- Tension Load Cell Signal Input (Single Channel)1 or 2 load cells from two separate tension zones connected to a channel 1 and 2 input
- Load Cell Excitation5 or 7.5 VDC, 200mADC maximum
- Load Cell Sensitivity1.5 to 100 mV/V, 500 mV maximum
- Display6-digit LED
- MountingDIN 35 Rail
- Operating Temperature0 to 60˚ C
- Storage Temperature-20 to 80˚ C
- EnclosureIP20
- CertificationsCE (EN61326-1)
TUV Mark (UL61010-1)
CAN/CSA-C22.2# 61010-1
CB to IEC 61010-1
RoHS
ODVA Conformant - Sampling frequency2 milliseconds (500 Hz)
- Tension A to D Resolution24 bit (14 bit average)
- Adjustable Filtering0.1 to 100 Hz, or can be turned off for raw data output of 500 Hz
- CommunicationsEtherNet/IP
PROFINET
Modbus TCP and an embedded web server page
EtherCAT - AlarmsTwo programable alarm outputs
30 VDC maximum, 0.4 ADC maximum - Ready to Run AlarmIndicates no errors, ready to operate
30 VDC maximum, 0.4 ADC maximum - Tare Adjustment90% of load cell rating
- Ethernet2 ports (10/100 Mbps)
- Digital Input (re-zero)24 VDC Maximum
5 VDC or 24 VDC slectable threshold - Analog Outputs0 to 10 VDC (2 kohm minimum load)
4 to 20 mADC, 450 ohm maximum load - Reference Meter Output0 to 1 mADC, 1 kohm maximum load
0 to 10 VDC open circuit
DLCA NET-SLIM SPECIFICATIONS
- Power Supply24 VDC, +/- 10%, 250mA maximum
- Tension Load Cell Signal Input (Single Channel)1 or 2 load cells from a single tension zone, connected to a left and right input
- Tension Load Cell Signal Input (Single Channel)1 or 2 load cells from two separate tension zones connected to a channel 1 and 2 input
- Load Cell Excitation5 or 7.5 VDC, 200mADC maximum
- Load Cell Sensitivity1.5 to 100 mV/V, 500 mV maximum
- MountingDin 35 rail
- Operating Temperature0 to 60˚ C
- Storage Temperature-20 to 80˚ C
- EnclosureIP20
- CertificationsCE (EN61326-1)
TUV Mark (UL61010-1)
CAN/CSA-C22.2# 61010-1
CB to IEC 61010-1
RoHS
ODVA Conformant - Sampling frequency2 milliseconds (500 Hz)
- Tension A to D Resolution24 bit (14 bit average)
- Adjustable Filtering0.1 to 100 Hz, or can be turned off for raw data output of 500 Hz
- CommunicationsEtherNet/IP
PROFINET
Modbus TCP and an embedded web server page
EtherCAT - AlarmsTwo programable
- Ready to Run AlarmIndicates no errors, ready to operate
- Tare Adjustment90% of load cell rating
- Ethernet2 ports (10/100 Mbps)
DLCA NET-IP65 SPECIFICATIONS
- Power Supply24 VDC, +/- 10%, 250mA maximum
- Tension Load Cell Signal Input (Single Channel)1 or 2 load cells from a single tension zone, connected to a left and right input
- Tension Load Cell Signal Input (Single Channel)1 or 2 load cells from two separate tension zones connected to a channel 1 and 2 input
- Load Cell Excitation5 or 7.5 VDC, 200mADC maximum
- Load Cell Sensitivity1.5 to 100 mV/V, 500 mV maximum
- MountingWall mount slots
- Operating Temperature0 to 60˚ C
- Storage Temperature-20 to 80˚ C
- EnclosureIP65
- CertificationsCE (EN61326-1)
TUV Mark (UL61010-1)
CAN/CSA-C22.2# 61010-1
CB to IEC 61010-1
RoHS
ODVA Conformant - Sampling frequency2 milliseconds (500 Hz)
- Tension A to D Resolution24 bit (14 bit average)
- Adjustable Filtering0.1 to 100 Hz, or can be turned off for raw data output of 500 Hz
- CommunicationsEtherNet/IP
PROFINET
Modbus TCP and an embedded web server page
EtherCAT - AlarmsTwo programable
- Ready to Run AlarmIndicates no errors, ready to operate
- Tare Adjustment90% of load cell rating
- Ethernet2 ports (10/100 Mbps)