Description
Features:
- Web Break Detection
- Out-of-Round Roll Compensation
- Bus Communication Capability
- Auto Tuning
- Weightless Load Cell Calibration
- Advanced Load Cell Diagnostics
- Gain Scheduling
- UL and CE Approved
MAGPOWR CYGNUS SPECIFICATIONS
- Certifications CE UL 508C Listed
Input
- Supply Voltage115/230 VAC +/- 10%, 50/60 Hz, switch selectable
- Tension Input0 to 21 mVDC (1 or 2, 350 Ω full bridges), 0 to 500 mVDC
(1 or 2, 120 Ω bridge), 0 to 5 VDC, 1 mADC maximum - Diameter Input0 to 10 VDC analog or calculated using velocity/rpm
- RPM or Web Speed0 to 10 VDC analog, or
0.01 to 50,000 pulses per second, 5 VDC or 24 VDC logic - Auxiliary Input0 to 10 VDC
- E-Stop, Run/Stop, Tension Off, Format, Spliceswitch closure,
5 or 24 VDC logic, active high or low
Output
- Torque0 to 10 VDC, 4 to 20 mADC (500 Ω max), -10 to +10 VDC
- Inverse Diameter0 to 10 VDC, 1 mADC maximum
- Tension Reference0 to 10 VDC, 1 mADC maximum
- Load Cell Excitation5 or 10 VDC, +5 and -5 VDC (10 VDC)
- Low Tension (Web Break) Tension StatusDC solid state relay, 100 mADC
with a 1.6 VDC drop, 30 VDC max, or
5 mADC with a 0.6 VDC drop 30 VDC maximum
Weight
- Cygnus-DIN4 lb
- Cygnus-E11 lb
Temperature
- E-Operating32 to 104˚ F
- DIN Operating32 to 122˚ F
- Storage-22 to 176˚ F
Enclosure
- Cygnus-DINFront Panel IP65 (IEC529)
Enclosure IP20 (IEC529) - Cygnus-EIP65 (IEC529)
Bus Communication Gateways
- COMMKIT-DNDeviceNet
- COMMKIT-ENEthernet/IP
- COMMKIT-PBProfibus-DP